TECHNICAL DATA - Air Cooled Type
TECHNICAL DATA (Air Cooled Type) - Single Type
SECTION AR-SPA-030 AR-SPA-050 AR-SPA-075 AR-SPA-100 AR-SPA -150
Cooling Cap.
23℃
kcal/h 8,570 15,600 20,500 31,900 38,900
KW 9.96 18.13 23.83 37.09 45.23
Ventilator Type SIROCCO FAN TYPE
Model AS-110D AS-111D AS-133D AS-1512D AS-1512D
Air Volume
(CMM)
33 55 80 110 160
Motor(KW) 0.4 0.75 0.75 1.12 3.7
Compressor Type HERMETIC
Power(KW) 2.11 3.79 5.04 7.5 9.7
Condenser Model ARCD-A030 ARCD-A050 ARCD-A075 ARCD-A100 ARCD-A150
Air Volume
(CMM)
68 120 200 220 300
Fan Dia
(mm)
450 550 500x2 550x2 600x2
Motor(KW) 0.16 0.4 0.3x2 0.4x2 0.55x2
Evaporator Type MULTI-PASS CROSS FINNED TUBE TYPE
Front Size(㎡) 0.264 0.455 0.572 0.829 1.12
Pipe Diameter Suction
(mm)
15.875 19.05 25.4 28.575 34.925
Discharge
(mm)
12.7 15.875 19.05 19.05 25.4
Liquid pipe
(mm)
9.525 12.7 12.7 15.875 22.225
Drain
(mm)
25.4 25.4 25.4 25.4 25.4
Refrigerant R-22
Power consumption (KW) 2.67 4.94 6.39 9.42 14.5
  Supply of electricty(V) 380(220)
Thickness of wire (㎟) 4(4) 4(6) 6(10) 10(16) 10(25)
Reference
1. Usage of electric power can be changed in the equipment.
2. Design standard : ET:7.2℃/ CT:54.5℃
3. Power consumption is based on design standard of nominal condition
TECHNICAL DATA - Air Cooled Type
TECHNICAL DATA (Air Cooled Type) - Dual Type
SECTION AR-DPA-060 AR-DPA-100 AR-DPA-150 AR-DPA-200 AR-DPA-300
Cooling Cap.
23℃
kcal/h 17,140 31,200 41,000 63,800 77,800
KW 19.93 36.26 47.67 74.18 90.46
Ventilator Type SIROCCO FAN TYPE
Model AS-122D AS-111Dx2 AS-133Dx2 AS-1512Dx2 AS-1512Dx2
Air Volume
(CMM)
66 110 160 220 330
Motor(KW) 0.75 0.75x2 0.75x2 1.12x2 3.7x2
Compressor Type HERMETIC
Power(KW) 2.11x2 3.79x2 5.25x2 7.5x2 9.7x2
Condenser Model ARCD-A030 ARCD-A050 ARCD-A075 ARCD-A100 ARCD-A150
Air Volume
(CMM)
136 240 400 440 600
Fan Dia
(mm)
450x2 550x2 500x4 550x4 600x4
Motor(KW) 0.16x2 0.4x2 0.3x2 0.4x2 0.55x2
Evaporator Type MULTI-PASS CROSS FINNED TUBE TYPE
Front Size(㎡) 0.525 0.96 1.335 1.831 2.34
Pipe Diameter Suction
(mm)
15.875 19.05 25.4 28.575 34.925
Discharge
(mm)
12.7 15.875 19.05 19.05 25.4
Liquid pipe
(mm)
9.525 12.7 12.7 15.875 22.225
Drain
(mm)
25.4 25.4 25.4 25.4 25.4
Refrigerant R-22
Power consumption (KW) 5.29 9.88 12.78 18.84 29
  Supply of electricty(V) 380(220)
Thickness of wire (㎟) 4(6) 6(16) 10(25) 16(35) 25(35)
Reference
1. Usage of electric power can be changed in the equipment.
2. Design standard : ET:7.2℃/ CT:54.5℃
3. Power consumption is based on design standard of nominal condition
TECHNICAL DATA - E-Glycol Type
TECHNICAL DATA (E-Glycol Type) - Single Type
SECTION AR-SPG-030 AR-SPG-050 AR-SPG-075 AR-SPG-100 AR-SPG -150
Cooling Cap.
23℃
kcal/h 8,570 15,600 20,500 31,900 38,900
KW 9.96 18.13 23.83 37.09 45.23
Ventilator Type SIROCCO FAN TYPE
Model AS-110D AS-111D AS-133D AS-1512D AS-1512D
Air Volume
(CMM)
33 55 80 110 160
Motor(KW) 0.4 0.75 0.75 1.12 3.7
Compressor Type HERMETIC
Power(KW) 2.11 3.79 5.04 7.5 9.7
Evaporator Type MULTI-PASS CROSS FINNED TUBE TYPE
Front Size(㎡) 0.264 0.455 0.572 0.829 1.12
Pipe Diameter Suction 15.875 19.05 25.4 28.575 34.925
Discharge 12.7 15.875 19.05 19.05 25.4
Liquid pipe 9.525 12.7 12.7 15.875 22.225
Drain 25.4 25.4 25.4 25.4 25.4
Plumbing 25A 32A 40A 50A 50A
Refrigerant R-22
Power
consumption
(KW) 2.51 4.54 5.79 8.62 13.4
  Supply of electricty(V) 380(220)
Thickness of wire (㎟) 4(4) 4(6) 6(10) 10(16) 10(25)
Reference
1. Usage of electric power can be changed in the equipment.
2. Design standard : ET:7.2℃/ CT:54.5℃
3. Power consumption is based on design standard of nominal condition
TECHNICAL DATA - E-Glycol Type
TECHNICAL DATA (E-Glycol Type) - Dual Type
SECTION AR-DPG-060 AR-DPG-100 AR-DPG-150 AR-DPG-200 AR-DPG-300
Cooling Cap.
23℃
kcal/h 17,140 31,200 41,000 63,800 77,800
KW 19.93 36.26 47.67 74.18 90.46
Ventilator Type SIROCCO FAN TYPE
Model AS-122D AS-111Dx2 AS-133Dx2 AS-1512Dx2 AS-1512Dx2
Air Volume
(CMM)
66 110 160 220 330
Motor(KW) 0.75 0.75x2 0.75x2 1.12x2 3.7x2
Compressor Type HERMETIC
Power(KW) 2.11x2 3.79x2 5.04x2 7.5x2 9.7x2
Evaporator Type MULTI-PASS CROSS FINNED TUBE TYPE
Front Size(㎡) 0.525 0.96 1.335 1.831 2.34
Pipe Diameter Suction 15.875 19.05 25.4 28.575 34.925
Discharge 12.7 15.875 19.05 19.05 25.4
Liquid pipe 9.525 12.7 12.7 15.875 22.225
Drain 25.4 25.4 25.4 25.4 25.4
Plumbing 40A 50A 50A 65A 80A
Refrigerant R-22
Power consumption (KW) 4.97 9.08 11.58 17.24 26.8
  Supply of electricty(V) 380(220)
Thickness of wire (㎟) 4(6) 6(16) 10(25) 16(35) 25(35)
Reference
1. Usage of electric power can be changed in the equipment.
2. Design standard : ET:7.2℃/ CT:54.5℃
3. Power consumption is based on design standard of nominal condition